NPort 5150AI-M12/NPort 5250AI-M12/NPort 5450AI-M12 Series Moxa Việt Nam
Xuất sứ: Taiwan
Nhà cung cấp: Moxa
Hãng sản xuất: MOXA VIỆT NAM
Ứng dụng sản phẩm: Thiết bị chuyển đổi tín hiệu RS 232/422/485 - Serial Device Server
Features and Benefits
- Speedy 3-step web-based configuration
- COM port grouping and UDP multicast applications
- Real COM/TTY drivers for Windows and Linux
- Standard TCP/IP interface and versatile TCP and UDP operation modes
- Complies with all EN 50155 mandatory test items*
- M12 connector and IP40 metal housing
- 2 kV isolation for serial signals
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: www.moxa.com/doc/specs/EN_50155_Compliance.pdf
Introduction
The NPort 5000AI-M12 serial device servers are designed to make serial devices network-ready in an instant, and provides direct access to serial devices from anywhere on the network. Moreover, the NPort 5000AI-M12 is compliant with EN 50121-4 and mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD, and vibration, making them suitable for rolling stock and wayside applications where high levels of vibration exist in the operating environment.a
3-step Web-based Configuration
The NPort 5000AI-M12’s 3-step web-based configuration tool is straightforward and user-friendly. The NPort 5000AI-M12’s web console guides users through 3 simple configuration steps that are necessary to activate the serial-to-Ethernet application. With this speedy 3-step web-based configuration, a user only needs to spend an average of 30 seconds to complete the NPort settings and enable the application, saving a great amount of time and effort.
Easy to Troubleshoot
NPort 5000AI-M12 device servers support SNMP, which can be used to monitor all units over Ethernet. Each unit can be configured to send trap messages automatically to the SNMP manager when user-defined errors are encountered. For users who do not use SNMP manager, an e-mail alert can be sent instead. Users can define the trigger for the alerts using Moxa’s Windows utility, or the web console. For example, alerts can be triggered by a warm start, a cold start, or a password change.
• Ethernet Interface | |
Number of Ports | 1 |
Speed | 10/100 Mbps, auto MDI/MDIX |
Connector | M12 D-coded 4-pin female connector |
• Serial Interface | |
Number of Ports | 1, 2, 4 |
Serial Standards | RS-232/422/485 |
Connector | DB9 male |
RS-485 Data Direction Control | ADDC® (Automatic Data Direction Control) |
• Serial Communication Parameters | |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 1.5, 2 |
Parity | None, Even, Odd, Space, Mark |
Flow Control | RTS/CTS and DTR/DSR (RS-232 only), XON/XOFF |
Baudrate | Supports standard baudrates (unit=bps):50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 19200, 38400, 57600, 115200, 230.4k, 460.8k, 921.6k |
• Serial Signals | |
RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
RS-422 | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-2w | Data+, Data-, GND |
• Software | |
Network Protocols | ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, IGMP V1/2, ARP, LLDP |
Configuration Options | Web Console (with new Quick Setup), Telnet Console, Windows Utility |
Windows Real COM Drivers | Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded |
Fixed TTY Drivers | SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X |
Linux Real TTY Drivers | Linux 2.4.x, 2.6.x, 3.x, 4.x |
Android API | Android 3.1.x and later |
• Physical Characteristics | |
Housing | Metal, IP40 protection |
Weight | 686 g (1.51 lb) |
Dimensions | 80 x 216.6 x 52.9 mm (3.15 x 8.53 x 2.08 in) |
• Environmental Limits | |
Operating Temperature | Standard Models: -25 to 55°C (-13 to 131°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Power Requirements | |
Input Voltage | 12 to 48 VDC |
Note | Compliant with EN 50155 on 24/48 VDC |
Input Current | NPort 5150AI-M12: 310 mA @ 12 VDC NPort 5250AI-M12: 360 mA @ 12 VDC NPort 5450AI-M12: 440 mA @ 12 VDC |
Connector | M12 5-pin male connector |
• Standards and Certifications | |
Safety | UL 60950-1 |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 2 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m IEC 61000-4 |
Rail Traffic | EN 50155*, EN 50121-4 |
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here | www.moxa.com/doc/specs/EN_50155_Compliance.pdf |
Vibration | IEC 60068-2-6 |
• Reliability | |
Alert Tools | Built-in buzzer and RTC (real-time clock) |
Automatic Reboot Trigger | Built-in WDT (watchdog timer) |
• MTBF (mean time between failures) | |
Time | NPort 5150AI-M12: 789,341 hrs NPort 5250AI-M12: 639,622 hrs NPort 5450AI-M12: 467,777 hrs |
Standard | Telcordia (Bellcore) Standard TR/SR |
• Warranty | |
Warranty Period | 5 years |